MAXA i-32V5 A16 heat pump (16kw)
5.565,00 VAT excluded
Category: Tag:

Disponibile

Brand: MAXA
Type: Monoblock hydronic heat pump

Requirement: Cooling/ Heating

Power: 16 kw

Energy Class: A+++ (35°C)
Ideal for rooms up to a maximum of 180 square meters
Refrigerant gas: R-32
Dimensions (HxWxD) : 1409 x 1044 x 448 mm
Power supply : Single phase
Warranty : 3 years with first ignition included mandatory

Recommended options:

  • Anti-vibration feet
  • Wall-mounted remote control

Certifications:

 

 

Download the manual

Se sei un installatore, scrivici per richiedere un offerta personalizzata

Description

TECHNICAL FEATURES

 

i-32V5

14T 16 16T 18T
 

 

 

 

 

Cooling

 

Cooling capacity (1) min/nom/max

 

kW

 

6,87 / 11,5 /12,1*

 

5,99 / 13,8 /14,5*

 

5,99 / 13,8 /14,5*

 

6,86 / 15,0 /15,8*

Power consumption (1) kW 3,53 4,38 4,38 4,88
E.E.R. (1) W/W 3,25 3,15 3,15 3,08
Cooling capacity (2) min/nom/max  

kW

,

9,17 / 14,0 /14,7*

 

9,20 / 15,8 /16,6*

 

9,20 / 15,8 /16,6*

 

9,09 / 17,1 /18,0*

Power consumption (2) kW 2,59 3,15 3,15 3,59
E.E.R. (2) W/W 5,40 5,02 5,02 4,76
SEER (5) W/W 4,77 4,94 4,94 5,05
Water flow rate (1) L/s 0,55 0,66 0,66 0,71
Use-side exchanger pressure drop (1) kPa 12,9 17.5 17,5 20,6
 

 

 

 

 

 

Heating

Thermal power (3) min/nom/max kW 7,54 / 14,1 /15,2* 7,36 / 16,3 /17,6* 7,36 / 16,3 /17,6* 7,30 / 17,9 /19,3*
Power consumption (3) kW 2,91 3,49 3,49 4,07
C.O.P. (3) W/W 4,85 4,67 4,67 4,40
Thermal power (4) ) min/nom/max kW 7,23 / 13,6 /14,6* 7,06 / 15,8 /17,0* 7,06 / 15,8 /17,0* 7,02 / 17,3 /18,7*
Power consumption (4) kW 3,55 4,24 4,24 4,92
C.O.P. (4) W/W 3,82 3,72 3,72 3,52
SCOP (6) W/W 4,48 4,50 4,50 4,46
Water flow rate (4) L/s 0,65 0,76 0,76 0,83
Use-side exchanger pressure drop (4) kPa 13,0 17,6 17,6 21,0
Energy Efficiency

water 35°C / 55°C

Class A+++/A++ A+++/A++ A+++/A++ A+++/A++
 

 

Compressor

Type Twin Rotary Dc Inverter
Number of compressors 1 1 1 1
Coolant oil(Type) ESTER OIL VG74
Coolant oil (Quantity) L 1,4 1,4 1,4 1,4
Cooling circuits 1 1 1 1
 

 

Coolant

Type R32 R32 R32 R32
Refrigerant Qty (7) kg 3,2 3,5 3,5 3,5
Refrigerant qty in tons of CO2 equivalent (7) ton 2,2 2,4 2,4 2,4
Design pressure (high/low) mod. heat pump bar 42,8/1,3 42,8/1,3 42,8/1,3 42,8/1,3
Design pressure (high/low) mod. chiller bar 42,8/3,5 42,8/3,5 42,8/3,5 42,8/3,5
Outdoor zone fans Type Brushless DC Motor
Number 2 2 2 2
Internal exchanger Internal exchanger type A plates
No. of internal exchangers 1 1 1 1
Water content L 1,7 1,7 1,7 1,7
 

 

 

Hydraulic circuit

Useful prevalence (1) kPa 75,0 62,3 62,3 55,6
Water content of hydronic circuit L 3,0 3,0 3,0 3,0
Maximum water-side pressure bar 6 6 6 6
Hydraulic connections inch 1 “M 1 “M 1 “M 1 “M
Minimum water volume (8) L 60 70 70 70
Maximum circulator power kW 0,14 0,14 0,14 0,14
Max circulator absorbed current A 1,10 1,10 1,10 1,10
Energy Efficiency Index (EEI) circulator ≤ 0,23 ≤ 0,23 ≤ 0,23 ≤ 0,23
Sound emissions Sound Power Lw (9) dB(A) 68 68 68 68
Sound Power Lw (10) dB(A) 66 66 66 66
 

 

Electrical data

Power supply 400V/3P+N+T/50Hz 230V/1/50Hz 400V/3P+N+T/50Hz 400V/3P+N+T/50Hz
Maximum power input kW 6,6 7,0 7,0 8,3
Maximum absorbed current A 9,5 30,4 10,1 12,0
Maximum power input with antifreeze kit kW 6,7 7,1 7,1 8,5
Maximum absorbed current with antifreeze kit A 9,7 31,0 10,3

12,2

Performance referred to the following conditions in accordance with 14511:2018:

(1) Cooling: outdoor air temperature 35°C; water temperature in/out. 12/7°C.

(2) Cooling: outdoor air temperature 35°C; inlet/outlet water temperature 23/18°C.

(3) Heating: outdoor air temperature 7°C b.s. 6°C b.u.; water temp.ing./exc. 30/35°C

(4) Heating:outdoor air temperature 7°C b.s. 6°C b.u.; water temp.ing./exc. 40/45°C.

(5) Cooling: inlet/outlet water temperature 7/12°C.

(6) Heating: average climatic conditions; Tbiv=-7°C; temp.water ing./usc. 30/35°C.

(7) Indicative data and subject to change. Always refer to the technical label on the unit for the correct figure.

(8) Calculated for a decrease in system water temperature of 20°C with a defrost cycle lasting 6 minutes.

(9) Sound power: heating mode condition (3) according to EN 12102-1:2013; value determined on the basis of measurements made in accordance

With the UNI EN ISO 9614-1 standard.

(10) Sound power: heating mode at part load according to annex A of EN 12102:2017; value determined based on measurements made

in accordance with UNI EN ISO 9614-1, in compliance with the requirements of Eurovent and Heat Pump Keymark certification.

(*) by activating the maximum Hz function.

N.B. Performance data shown are approximate and may be subject to change. In addition, the yields declared in (1), (2), (3) and (4)

are intended to refer to instantaneous power according to UNI EN 14511. The figure stated in (5) and (6) is determined according to UNI

EN 14825.

Additional information

Weight 160 kg

Servizio clienti


Associata al consorzio

Copyright 2024 by  Enerinvest srl   REA FG-258455 Iscritta al registro nazionale pile e accumulatori con il n° 23030P00008569 e al registro nazionale dei produttori di apparecchiature elettriche ed elettroniche con il n° IT23030000014701 

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.